Browsing by Author "Bennett, Hayden Albert Edward"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemAspects of fouling in dairy processing : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Food Engineering at Massey University, Palmerston North, New Zealand(Massey University, 2007) Bennett, Hayden Albert EdwardFouling of heat treatment equipment in the dairy processing industry is an expensive and persistent problem. The objective of this work was to develop a better understanding of the mechanisms of dairy fouling in heat exchangers and identify methods to control this build-up. This was part of a larger project investigating the interaction between spore-forming thermophilic bacilli (thermophiles) contamination and fouling deposits on internal surfaces of equipment. Two systems were developed to monitor the onset and build-up of fouling on the internal surfaces of two research heat exchangers. The first used a commercial sensor to measure the local heat flux and the temperature on the hot side of a plate type heat exchanger. The heat transfer coefficient was calculated and normalised with its value at the start of the run to reflect the contribution of fouling deposits to the thermal resistance, thus giving a real-time estimate of the rate of fouling. The second system used an energy balance over a tubular type heat exchanger and measured inlet and outlet temperatures to estimate the overall heat transfer coefficient thus giving a global measurement of fouling over the tubular heat exchanger. In both systems the plot of normalised heat transfer coefficient over time often stayed constant over an induction period, which was followed by a falling period indicative of growth in the fouling layer thickness and/or mass. Each system was validated by comparing the final value of the normalised heat transfer coefficient with direct measurements of fouling made at the end of a run namely: fouling deposit height for the local measurement and fouling deposit mass for the global measurement. The normalised heat transfer coefficient reported by each system correlated well with the corresponding direct measurement of the fouling layer. An important factor identified in this study was the effect of air bubble nucleation on fouling deposits. It was shown that bubbles that formed on the heated surface greatly reduced the length of the induction period to a matter of seconds rather than hours, as found in previous studies of fouling in the absence of surface bubbles. The rate of fouling was also enhanced while the bubbles remained at the surface. The structure of bubble type fouling layers was linked to the behaviour of the bubbles at the heated surface. Visual observations of these bubbles showed evidence of growth, vibration and coalescence during their period of attachment to the heated surface. Deposits from bubble type fouling consisted of all solid components found in the original milk solution, except lactose, in approximately the same ratio. By contrast fouling deposits reported in the literature with systems operating under the traditional protein denaturation mechanism were reported to consist mainly of whey proteins. Bubble induced fouling can be limited in a number of ways, the most effective being to maintain a high operating pressure in the equipment to ensure nucleation does not occur. Experiments conducted in this study showed that a pressure of 130 kPa.g was sufficient to suppress all bubble nucleation at the heated surface at a temperature of 90°C. Another method identified was the use of high linear fluid velocities to entrain any surface bubbles into the processing stream immediately upon nucleation. Linear velocities above 1.0 m/s were shown to achieve this goal in the miniature plate heat exchanger tested. However, this method is only partially successful because the local linear velocity varies with position in heat exchange equipment of complex geometries and can drop below the mainstream average velocity causing surface bubbles to form, especially in recirculation regions behind flow obstacles. A more reliable method, in situations where high operating pressures could not be used, involved conditioning the heated surface with a thin protein layer during the first few minutes of a run. Conditioning the surface resulted in bubble suppression even at high temperatures and low pressures, thus greatly extending the length of the induction period. Trials performed in this study showed that the addition of a proteolytic enzyme produced by psychrotrophic microbes greatly increased fouling. The enzyme destabilised the caseins which could attach directly to the heat exchange surface independently from the bubble fouling mechanism. Thus the quality of the milk is another important factor to consider. However, the addition of enzymes produced by thermophilic bacilli isolated from milk powder plants did not increase fouling. A theory describing the air bubble induced fouling mechanism is presented along with recommendations on how to reduce this fouling contamination in processing equipment.
- ItemWhole milk fouling of heated surfaces : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology in Food Engineering at Massey University(Massey University, 2000) Bennett, Hayden Albert EdwardWhole milk fouling of surfaces within dairy products processing plants, especially that which occurs on heat treatment equipment, is an important operating problem, threatening the quality of product and reducing thermal and mechanical efficiency of equipment. A fouling monitoring system was developed using a commercial heat flux probe and temperature sensor. The fouling monitor was installed in two unit operations of a custom built milk powder pilot plant. The unit operations replicated heat treatments found in plate heat exchangers and falling film evaporators. The research plate heat exchanger consisted of six miniature plate heat exchangers or modules in series. Individual modules could be isolated at any point during a run allowing access to the fouling deposit. The research falling film evaporator was a flat plate attached to a steam chamber and milk weir box. The onset and build-up of whole milk fouling on the evaporator plate was viewed through a sight window installed in the evaporator casing. Trials conducted with the research plate heat exchanger showed that the monitoring system could detect whole milk fouling in terms of a reduction in the overall heat transfer coefficient. This reduction was shown to directly correspond to an increase in fouling deposit thickness. For the same bulk milk temperature, the fouling rate decreased significantly when the surface was unheated compared with heated surfaces. This observation lead to a set of experiments that manipulated the start up procedure on both the milk and heating medium side of the research plate heat exchanger. More fouling was observed on plates after air start up (on the milk side) than on plates after water start up. Similarly, Surface Conditioning by Operational Protocol (SCOP) extended the fouling induction period. The SCOP trials compared steady state heating with unsteady state heating during start-up. Similar amounts of fouling were observed on plates removed from the steady state heated modules after 30 minutes and on plates removed from the unsteady state modules after 9 hours. These results indicate that the state of the stainless steel surface when the. milk first makes contact has an important effect on the subsequent rate of fouling. It is recommended that future work aims to identify which milk components deposit first onto the surface and what influence they have on inhibiting or facilitating fouling. The fouling monitoring system successfully estimated the extent of fouling for all of the trials. Industry trials for the fouling monitoring system, particularly on heated surfaces are recommended. The system will allow local areas of intense fouling to be mapped within the processing plants. A number of recommendations are presented concerning future work associated with start up procedure manipulation, evaporator trials and seasonal variation trials.