Repository logo
    Info Pages
    Content PolicyCopyright & Access InfoDepositing to MRODeposit LicenseDeposit License SummaryFile FormatsTheses FAQDoctoral Thesis Deposit
    Communities & Collections
    All of MRO
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register using a personal email and password.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Kate Shoveller A"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Item
    Development and validation of an LC-MS/MS method for the quantification of oral-sugar probes in plasma to test small intestinal permeability and absorptive capacity in the domestic cat (Felis catus)
    (Elsevier BV, 2024-07-15) Patterson K; Fraser K; Bernstein D; Bermingham EN; Weidgraaf K; Kate Shoveller A; Thomas D
    A novel method for quantifying the concentration of lactulose, rhamnose, xylose, and 3-O-methylglucose (3-OMG) in cat plasma using liquid chromatography-mass spectrometry (LC-MS) was developed. Domestic male cats (n = 13) were orally dosed with a solution containing the four sugars to test the permeability and absorptive capacity of their intestinal barrier. Plasma samples were taken 3 h later and were prepared with acetonitrile (ACN), dried under N2, and reconstituted in 90 % ACN with 1 mM ammonium formate. Stable isotope labelled 13C standards for each analyte were used as internal standards. Chromatographic separation was conducted using a Phenomenex Luna NH2 column with a gradient elution system of deionized water and 90 % ACN with 1 mM ammonium formate at 300 µL/min for 13 min total analysis time. Recovery trials were conducted in triplicate over three days with RSD values (%) for each day ranging from 1.2 to 1.4 for lactulose, 5.4 - 6.0 for rhamnose, 3.3 - 5.5 for xylose, and 2.6 - 5.6 for 3-OMG. Inter-day variations for each analyte were not different (p > 0.05). Limit of detection and quantification were 0.2 and 0.7 µg/mL for lactulose, 0.8 and 2.4 µg/mL for rhamnose, 0.6 and 1.8 µg/mL for xylose, and 0.3 and 1.1 µg/mL for 3-OMG, respectively. Plasma sugar concentrations recovered from cats were above the limit of quantification and below the highest calibration standard, validating the use of this method to test intestinal permeability and absorptive capacity in cats.

Copyright © Massey University  |  DSpace software copyright © 2002-2026 LYRASIS

  • Contact Us
  • Copyright Take Down Request
  • Massey University Privacy Statement
  • Cookie settings
Repository logo COAR Notify