Repository logo
    Info Pages
    Content PolicyCopyright & Access InfoDepositing to MRODeposit LicenseDeposit License SummaryFile FormatsTheses FAQDoctoral Thesis Deposit
    Communities & Collections
    All of MRO
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register using a personal email and password.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Thomson J"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Item
    Reliability of a 60-min treadmill running protocol in the heat: The journal Temperature toolbox
    (Taylor and Francis Group, 2022-11-11) Mündel T; Gilmour S; Kruger M; Thomson J
    We determined the reliability of a 60-min treadmill protocol in the heat when spaced >4 weeks apart, longer than the test–retest duration of 1 week found in the literature. Nine unacclimated, trained males (age: 31 ± 8 y; VO2peak: 60 ± 6 ml∙kg−1∙min−1) undertook a 15 min self-paced time-trial pre-loaded with 45 min of running at 70% of individual ventilatory threshold (11.2 ± 0.3 km∙h−1) in 30 ± 1°C (53 ± 5% relative humidity). They repeated this following 40 ± 14 and 76 ± 26 days, with pre-trial standardization of diet and exercise for 48 h. When considering trial 1 as a familiarization, change in core temperature (∆Tcore) during the first 45 min (∆2.0 ± 0.2°C) between trials 2 and 3 yielded bias and 95% limits of agreement (LoA) of −0.10 ± 0.43°C, standard error of measurement (SEM) of 0.13°C and intraclass correlation coefficient (ICC) of 0.75, more reliable than measures of baseline Tcore (36.9 ± 0.2°C; LoA: −0.23 ± 0.90°C; SEM: 0.22°C; ICC: 0.03) and Tcore at 45 min during exercise (38.9 ± 0.4°C; LoA: 0.32 ± 1.12°C; SEM: 0.28°C; ICC: 0.15). The coefficient of variation (CV) between trials 2 and 3 for distance run during the 15 min time-trial was 2.1 ± 2.0% with LoA of 0.001 ± 0.253 km and SEM of 0.037 km. This protocol is reliable spaced ~5 weeks apart when considering the most commonly accepted limit of <5% CV for performance, reinforced by reliability of the ΔTcore being 0.1 ± 0.4°C.

Copyright © Massey University  |  DSpace software copyright © 2002-2026 LYRASIS

  • Contact Us
  • Copyright Take Down Request
  • Massey University Privacy Statement
  • Cookie settings
Repository logo COAR Notify