Browsing by Author "Zeng H"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemAre individual stock returns predictable?(SAGE Publications on behalf of the University of New South Wales, 2022-02) Zeng H; Marshall BR; Nguyen NH; Visaltanachoti NWe show that the previously documented predictability of macroeconomic and technical variables for market returns is also evident in individual stock returns. Technical variables generate better predictability on firms with high limits to arbitrage (small, illiquid, volatile firms), while macroeconomic variables better predict firms with low limits to arbitrage. Technical predictors show a stronger predictive power for high limits to arbitrage firms across the business cycle, whereas macroeconomic variables capture more predictive information for firms with low limits to arbitrage during recessions.
- ItemAssessment of clinical feasibility:offline adaptive radiotherapy for lung cancer utilizing kV iCBCT and UNet++ based deep learning model.(Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine, 2024-11-29) Zeng H; Chen Q; E X; Feng Y; Lv M; Zeng S; Shen W; Guan W; Zhang Y; Zhao R; Wang S; Yu JBackground Lung cancer poses a significant global health challenge. Adaptive radiotherapy (ART) addresses uncertainties due to lung tumor dynamics. We aimed to investigate a comprehensively and systematically validated offline ART regimen with high clinical feasibility for lung cancer. Methods This study enrolled 102 lung cancer patients, who underwent kV iterative cone-beam computed tomography (iCBCT). Data collection included iCBCT and planning CT (pCT) scans. Among these, data from 70 patients were employed for training the UNet++ based deep learning model, while 15 patients were allocated for testing the model. The model transformed iCBCT into adaptive CT (aCT). Clinical radiotherapy feasibility was verified in 17 patients. The dosimetric evaluation encompassed GTV, organs at risk (OARs), and monitor units (MU), while delivery accuracy was validated using ArcCHECK and thermoluminescent dosimeter (TLD) detectors. Results The UNet++ based deep learning model substantially improved image quality, reducing mean absolute error (MAE) by 70.05%, increasing peak signal-to-noise ratio (PSNR) by 17.97%, structural similarity (SSIM) by 7.41%, and the Hounsfield Units (HU) of aCT approaching a closer proximity to pCT compared to kV iCBCT. There were no significant differences observed in the dosimetric parameters of GTV and OARs between the aCT and pCT plans, confirming the accuracy of the dose maps in ART plans. Similarly, MU manifested no notable disparities, underscoring the consistency in treatment efficiency. Gamma passing rates for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans derived from aCT and pCT exceeded 98%, while the deviations in TLD measurements (within 2% to 7%) also exhibited no significant differences, thus corroborating the precision of dose delivery. Conclusion An offline ART regimen utilizing kV iCBCT and UNet++ based deep learning model is clinically feasible for lung cancer treatment. This approach provides enhanced image quality, comparable treatment plans to pCT, and precise dose delivery.