    Investigating office buildings evacuations using unannounced fire drills: The case study of CERN, Switzerland
    (2021-10-01) Rahouti A; Lovreglio R; Dias C; Kuligowski E; Gai G; La Mendola S
    The main objective of this paper is to explore evacuees’ behaviour during an unannounced fire drill using data collected in two office buildings located at CERN, in Switzerland. Overall, a total of 142 pre-evacuation time measurements, 121 evacuee walking speed measurements in staircase configurations, and 336 evacuee walking speed measurements on floor configurations are included in the dataset. These data were compared with the existing evacuation data for office buildings. This comparison revealed that the pre-evacuation times measured in the present study are significantly lower compared to existing data from the literature for the same type of occupancy. Walking speed data collected in corridors in the present study is within the range of the values reported in previous studies. Further, walking speeds on descending stairways measured in the present study were significantly higher than those available in the literature. However, the novel dataset presented in this study is in accordance with the values recommended in well-known guidelines (such as the SFPE Handbook) and could be used in the future to simulate evacuations of office buildings.
  • Item
    Enhancing egress drills: Preparation and assessment of evacuee performance
    (1/10/2019) Gwynne SMV; Kuligowski ED; Boyce KE; Nilsson D; Robbins AP; Lovreglio R; Thomas JR; Roy-Poirier A
    This article explores how egress drills—specifically those related to fire incidents—are currently used, their impact on safety levels, and the insights gained from them. It is suggested that neither the merits of egress drills are well understood, nor the impact on egress performance well characterized. In addition, the manner in which they are conducted varies both between and within regulatory jurisdictions. By investigating their strengths and limitations, this article suggests opportunities for their enhancement possibly through the use of other egress models to support and expand upon the benefits provided. It is by no means suggested that drills are not important to evacuation safety—only that their inconsistent use and the interpretation of the results produced may mean we (as researchers, practitioners, regulators, and stakeholders) are not getting the maximum benefit out of this important tool. © 2017 Her Majesty the Queen in Right of Canada. Fire and Materials StartCopText© 2017 John Wiley & Sons, Ltd.