Massey Documents by Type
Permanent URI for this communityhttps://mro.massey.ac.nz/handle/10179/294
Browse
2 results
Search Results
Item The particle size distribution of solid foods after human mastication : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Food Technology at Massey University, Auckland, New Zealand(Massey University, 2012) Flynn, Christine SandraBolus formation is a complex process for which two theories are generally accepted, both theories describe how food changes through the mastication process which results in specific properties of the bolus being detected in the mouth to initiate swallowing. This research aimed to identify how food type, portion size (2 g and 4 g) and subjects affects the fate of ingested food solids and their particle size distributions, and bolus moisture content at the swallow point. Then the dynamics of bolus formation up to and past the point of natural swallowing were investigated by the use of a single subject to identify key trends. Trials involved up to five processed foods; subjects were asked to chew portions of food and expectorate the bolus at the point they felt ready to swallow, or to expectorate the bolus at a specific number of chewing cycles. The solids loss from the bolus and moisture content of the bolus was determined. Particle size distribution (PSD) was measured for the expectorated bolus, and the debris (solids rinsed from the mouth after the bolus). The food type had the greatest influence on the bolus moisture content, loss of solids from the bolus and PSD of the bolus and debris fractions. Solids are lost from the bolus progressively from the first chew cycle. PSD differed significantly between the bolus and debris fractions, and the PSDs were characteristic for each food type. The rate of change in PSD appears to plateau near the swallow point for some foods, whilst moisture addition continues to increase up to and past the point of swallowing. The bolus moisture content at the swallow point was approximately 50%, despite the differences in chewing strategy between subjects. Saliva does not appear to be added at a constant rate due to no significant effect of portion size. The results from these studies indicate that bolus does not have to meet specific particle size criteria to achieve a safe swallow, and that particles circulate in multiple compartments during mastication. Results suggest a defined moisture content is required for a safe swallow.Item Evaluation of Kahne rumen sensors in fistulated sheep and cattle under contrasting feeding conditions : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Agriculture at Massey University, Palmerston North, New Zealand(Massey University, 2009) Lin, XiaoxiaoThe Kahne rumen sensor (bolus) is a device developed to measure temperature, pressure and pH in non-fistulated animals. This bolus allows real-time monitoring of the rumen environment, which could help preventing health problems such as rumen acidosis in cows. It is less invasive to use boluses compared to other technologies that measure the ruminal pH (e.g. rumenocentesis). Kahne boluses and transceivers are commercially available in the market. Several studies on the relationships between data recorded by the bolus and actual data recorded by independent devices were conducted. The bolus temperature and pressure were compared with actual temperature and pressure under controlled conditions. The pH drift was studied by comparing the difference between bolus and direct measurement over time. The capture of the data was calculated for each bolus in various experiments to examine the factors affecting the data capture rate of the boluses. Animal to animal variation was studied using boluses in a group of cows fed and managed under uniform conditions. An animal experiment involving fistulated cows eating two different diets was performed using boluses to monitor the changes of ruminal pH. There was no apparent interruption to normal animal behaviour as a result of using boluses. Regression relationships between bolus measurements and actual data for both temperature and pressure were developed and used for calibration of bolus data. The pH drift was a problem, as the regression relation between the pH difference and the time for one bolus from one experiment could not represent this bolus on other experiment. The data capture rate on the hourly basis ranged from 0 to 100%, but was usually between 30 to 70%. The data capture rate was affected by many factors and further studies to identify these factors are needed. A study of animal to animal variation suggests that in a comparison of 2 treatments, a minimum 3 cows per group would be required to detect the standard deviation of 0.11 for a pH difference of 5% of the mean (approximately 0.35 pH units). Seventeen cows per group would be required to detect the standard deviation of 0.33 for the same difference. The boluses effectively monitored the ruminal pH change in cows easting two different diets and the profile of change of pH was successfully analysed. Feeding 7.6 kg baleage twice a day cause pH to decrease at 0.009 pH units per minute during feeding, while offering a similar quantity of grass and hay once a day resulted in a decrease of 0.0009 pH units per minute during feeding. The beginning of pH increase was about 1 hour following feeding and continuous during resting and rumination. The level of pH increase did not differ significantly for two diets.. The Kahne devices appear to have advantages compared to other technologies for the measurement of parameters of the rumen environment on a real-time basis. Boluses are especially good at intensively monitoring the temperature, pressure, and pH in the rumen. The major limitations of this technology to be used are the data capture rate and the pH drift. By improving the limitations found in the experiment, the Kahne rumen sensor could become very useful for both scientific research and under commercial conditions for monitoring animal health.
