    Enzyme chemical engineering and its application to biosensors : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Chemistry at Massey University, Turitea, New Zealand

    Icon
    View/Open Full Text
    01_front.pdf (1.114Mb)
    02_whole.pdf (10.71Mb)
    Export to EndNote
    Abstract
    Enzyme chemical engineering is a fast growing area in biotechnology. It has been used to change the stability, solubility, activity and other properties of enzymes for more control over and wider application of enzymes. In this thesis, this technology is applied to another new and fast growing area of research: biosensors. Over the last decade, biosensors are gaining increasing awareness as a highly attractive analytical tool. One of the current challenges in this area is to identify a universal and scaleable way to produce sensitive, stable, instantaneous, and easy to prepare biosensors for mass production. In this study, enzyme chemical engineering is adopted as a new approach and glucose oxidase is served as a model to build a biosensor system in attempting to address the above challenge. In the study, glucose oxidase was used as the catalyst to chemically amplify the redox reaction of glucose. Haemin was employed as the bifunctional promoter to act as a "bridge" to connect glucose oxidase (GOD) and electrode. Haemin, similar to ferrocene also acts as a mediator to transfer electrons between the active center of the enzyme and the electrode. In the construction of a haemin-glucose oxidase biosensor, haemin was covalently bound with glucose oxidase. The haemin-glucose oxidase conjugate was then chemisorbed on to the platinum electrode to modify the electrode surface and form an "enzymatic redox center-bridge-electrode" system. The modification of the glucose oxidase with haemin comprised of two steps: converting the haemin carboxyl group to the reactive enol ester and then covalently bonding to an amino group of glucose oxidase. For chemisorption, the electrode was soaked in a solution of the haemin-glucose oxidase conjugate in phosphate buffer solution (pH 7.0) at 4°C for 16 hours. The same experiment was carried out by using unmodified glucose oxidase as a blank. The following facts proved that the covalently bound haemin-glucose oxidase system was formed successfully: 1) The large molecule fractions eluted from the Sephadex G-10 gel column had the enzyme activity and other characteristics of glucose oxidase. 2) The same fractions retained about 2/3 to 3/4 of the specific activity of original glucose oxidase. 3) The absorbance spectra of these fractions showed the peaks corresponding to both haemin and glucose oxidase. The following evidence suggests that the haemin-glucose oxidase conjugate was successfully chemisorbed on to the electrode surface: 1) The cyclic voltammogram of the electrode chemisorbed with conjugate was completely different from that adsorbed with glucose oxidase alone. 2) The cyclic voltammogram of the conjugate chemisorbed electrode in the solution with glucose was quite distinct from that without glucose. Thus a different species from either glucose oxidase or haemin was chemiabsorbed on to the electrode. Furthermore, the conjugate chemisorbed electrode showed linearity between current response and glucose concentration at a range from 0mM to 10mM. The ratio of the current response to glucose concentration was about 1.6µA/mM. However, the platinum electrode adsorbed by GOD alone had a poor response to glucose. The response time of the system of platinum electrode-haemin-glucose oxidase was very rapid at less than one minute, and the response fell initially but then remained stable over a period of 14 days. Thus the experimental data proved that the system of platinum electrode-haemin-glucose oxidase met the requirements for a glucose sensor in the factors of the sensitivity, linear response range, lifetime, ease of preparation, convenience of operation, non-toxicity and low cost. In other words, it demonstrated the characteristics of a glucose biosensor. Finally, using the preparation of this glucose biosensor as a model, the electrochemical mechanism of the biosensor system was proposed. The model was also used to suggest a systematic approach for constructing amperometric biosensors. The extension of this approach and the potential applications of this type of biosensor are also discussed.
    Date
    2001
    Author
    Luo, Wen
    Rights
    The Author
    Publisher
    Massey University
    URI
    http://hdl.handle.net/10179/12255
    Collections
    • Theses and Dissertations
    Metadata
    Show full item record

    Copyright © Massey University
    | Contact Us | Feedback | Copyright Take Down Request | Massey University Privacy Statement
    DSpace software copyright © Duraspace
    v5.7-2020.1-beta1
     

     

    Tweets by @Massey_Research
    Information PagesContent PolicyDepositing content to MROCopyright and Access InformationDeposit LicenseDeposit License SummaryTheses FAQFile FormatsDoctoral Thesis Deposit

    Browse

    All of MROCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Copyright © Massey University
    | Contact Us | Feedback | Copyright Take Down Request | Massey University Privacy Statement
    DSpace software copyright © Duraspace
    v5.7-2020.1-beta1