RAMAN AND ATR-FTIR SPECTROSCOPY TOWARDS CLASSIFICATION OF WET BLUE BOVINE LEATHER USING RATIOMETRIC AND CHEMOMETRIC ANALYSIS

dc.citation.issue1
dc.citation.volume2
dc.contributor.authorMehta M
dc.contributor.authorNaffa R
dc.contributor.authorMaidment C
dc.contributor.authorHolmes G
dc.contributor.authorWaterland M
dc.date.accessioned2024-01-28T19:55:45Z
dc.date.accessioned2024-07-25T06:32:52Z
dc.date.available2020-02-05
dc.date.available2024-01-28T19:55:45Z
dc.date.available2024-07-25T06:32:52Z
dc.date.issued2020-12
dc.description.abstractThere is a substantial loss of value in bovine leather every year due to a leather quality defect known as “looseness”. Data show that 7% of domestic hide production is affected to some degree, with a loss of $35 m in export returns. This investigation is devoted to gaining a better understanding of tight and loose wet blue leather based on vibrational spectroscopy observations of its structural variations caused by physical and chemical changes that also affect the tensile and tear strength. Several regions from the wet blue leather were selected for analysis. Samples of wet blue bovine leather were collected and studied in the sliced form using Raman spectroscopy (using 532 nm excitation laser) and Attenuated Total Reflectance - Fourier Transform InfraRed (ATR-FTIR) spectroscopy. The purpose of this study was to use ATR-FTIR and Raman spectra to classify distal axilla (DA) and official sampling position (OSP) leather samples and then employ univariate or multivariate analysis or both. For univariate analysis, the 1448 cm− 1 (CH2 deformation) band and the 1669 cm− 1 (Amide I) band were used for evaluating the lipid-to-protein ratio from OSP and DA Raman and IR spectra as indicators of leather quality. Curve-fitting by the sums-of-Gaussians method was used to calculate the peak area ratios of 1448 and 1669 cm− 1 band. The ratio values obtained for DA and OSP are 0.57 ± 0.099, 0.73 ± 0.063 for Raman and 0.40 ± 0.06 and 0.50 ± 0.09 for ATR-FTIR. The results provide significant insight into how these regions can be classified. Further, to identify the spectral changes in the secondary structures of collagen, the Amide I region (1600–1700 cm− 1) was investigated and curve-fitted-area ratios were calculated. The 1648:1681 cm− 1 (non-reducing: reducing collagen types) band area ratios were used for Raman and 1632:1650 cm− 1 (triple helix: α-like helix collagen) for IR. The ratios show a significant difference between the two classes. To support this qualitative analysis, logistic regression was performed on the univariate data to classify the samples quantitatively into one of the two groups. Accuracy for Raman data was 90% and for ATR-FTIR data 100%. Both Raman and ATR-FTIR complemented each other very well in differentiating the two groups. As a comparison, and to reconfirm the classification, multivariate analysis was performed using Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA). The results obtained indicate good classification between the two leather groups based on protein and lipid content. Principal component score 2 (PC2) distinguishes OSP and DA by symmetrically grouping samples at positive and negative extremes. The study demonstrates an excellent model for wider research on vibrational spectroscopy for early and rapid diagnosis of leather quality.
dc.description.confidentialfalse
dc.edition.editionDecember 2020
dc.identifier.citationMehta M, Naffa R, Maidment C, Holmes G, Waterland M. (2020). RAMAN AND ATR-FTIR SPECTROSCOPY TOWARDS CLASSIFICATION OF WET BLUE BOVINE LEATHER USING RATIOMETRIC AND CHEMOMETRIC ANALYSIS. Journal of Leather Science and Engineering. 2. 1.
dc.identifier.doi10.1186/s42825-019-0017-5
dc.identifier.eissn2524-7859
dc.identifier.elements-typejournal-article
dc.identifier.issn2097-1419
dc.identifier.number3
dc.identifier.piis42825-019-0017-5
dc.identifier.urihttps://mro.massey.ac.nz/handle/10179/70389
dc.languageEnglish
dc.publisherBioMed Central Ltd
dc.publisher.urihttps://jlse.springeropen.com/articles/10.1186/s42825-019-0017-5
dc.relation.isPartOfJournal of Leather Science and Engineering
dc.rights(c) 2020 The Author/s
dc.rightsCC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectRaman spectroscopy
dc.subjectAttenuated Total reflectance - Fourier transform InfraRed spectroscopy
dc.subjectPrincipal component analysis
dc.subjectLinear discriminant analysis
dc.subjectWet blue
dc.subjectDistal axilla
dc.subjectOfficial sampling position
dc.titleRAMAN AND ATR-FTIR SPECTROSCOPY TOWARDS CLASSIFICATION OF WET BLUE BOVINE LEATHER USING RATIOMETRIC AND CHEMOMETRIC ANALYSIS
dc.typeJournal article
pubs.elements-id454951
pubs.organisational-groupOther
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Evidence
Size:
329.97 KB
Format:
Microsoft Word XML
Description:
Loading...
Thumbnail Image
Name:
Published version
Size:
2.22 MB
Format:
Adobe Portable Document Format
Description:
Collections