Improving heating plant emissions using flue gas carbon monoxide monitoring : a thesis presented in partial fulfilment of the requirements for the degree of Masters of Engineering in Automation and Control at Massey University

dc.contributor.authorAl Shukairi, Jokha Hamood
dc.date.accessioned2011-12-07T22:52:00Z
dc.date.available2011-12-07T22:52:00Z
dc.date.issued2011
dc.description.abstractRCR Energy Systems builds industrial heating plants and their control systems. In these the excess air (above the stoichiometric ratio) for combustion is a process variable and its setpoint is determined using a look-up table. RCR aims to improve the efficiency of wood-fired, thermal-oil heating plants by using a combination of carbon monoxide monitoring and oxygen trim control to automatically adjust the excess air setpoint. Heating plants require the correct amount of oxygen for combustion. Too little excess air does not allow complete combustion, producing a loss in efficiency and wasted fuel. Too much excess air reduces the flame temperature with a consequent drop in heat transfer rate and loss of efficiency. The aim of the project was to explore the advantages of carbon monoxide monitoring and oxygen trim control, as well as its application, design and implementation in trimming excess oxygen setpoint, to a lower, but still safe operating level. Various carbon monoxide monitoring and oxygen trim control schemes were researched with the most suitable being implemented on an industrial system using a combined carbon monoxide and oxygen measurement analysers. This scheme was then tested on the heating plants at Hyne & Son in Tumbarumba, Australia. The tests proved that the excess air setpoint could be successfully reduced by 2%, leading to an approximate 3 – 5% improvement in efficiency.en_US
dc.identifier.urihttp://hdl.handle.net/10179/2905
dc.language.isoenen_US
dc.publisherMassey Universityen_US
dc.rightsThe Authoren_US
dc.subjectHeating plantsen_US
dc.subjectEnvironmental aspectsen_US
dc.subjectCarbon monoxide detectorsen_US
dc.subjectMeasurementen_US
dc.subjectAir quality managementen_US
dc.titleImproving heating plant emissions using flue gas carbon monoxide monitoring : a thesis presented in partial fulfilment of the requirements for the degree of Masters of Engineering in Automation and Control at Massey Universityen_US
dc.typeThesisen_US
massey.contributor.authorAl Shukairi, Jokha Hamood
thesis.degree.disciplineAutomation and Control
thesis.degree.grantorMassey University
thesis.degree.levelMasters
thesis.degree.nameMaster of Engineering (M.E.)
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
02_whole.pdf
Size:
1.75 MB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
01_front.pdf
Size:
110.42 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
804 B
Format:
Item-specific license agreed upon to submission
Description: