Biomechanical comparison of titanium alloy additively manufactured and conventionally manufactured plate-screw constructs.

dc.citation.issue1
dc.citation.volume72
dc.contributor.authorPolak S
dc.contributor.authorBeever L
dc.contributor.authorWade A
dc.contributor.authorFukuoka M
dc.contributor.authorWorth AJ
dc.coverage.spatialEngland
dc.date.accessioned2024-08-11T23:16:09Z
dc.date.available2024-08-11T23:16:09Z
dc.date.issued2023-12-10
dc.description.abstractAIM: To biomechanically compare the bending stiffness, strength, and cyclic fatigue of titanium additively manufactured (AM) and conventionally manufactured (CM) limited contact plates (LCP) of equivalent dimensions using plate-screw constructs. METHODS: Twenty-four 1.5/2.0-mm plate constructs (CM: n = 12; AM: n = 12) were placed under 4-point bending conditions. Data were collected during quasi-static single cycle to failure and cyclic fatigue testing until implants plastically deformed or failed. Bending stiffness, bending structural stiffness, and bending strength were determined from load-displacement curves. Fatigue life was determined as number of cycles to failure. Median test variables for each method were compared using the Wilcoxon rank sum test within each group. Fatigue data was also analysed by the Kaplan-Meier estimator of survival function. RESULTS: There was no evidence for a difference in bending stiffness and bending structural stiffness between AM and CM constructs. However, AM constructs exhibited greater bending strength (median 3.07 (min 3.0, max 3.4) Nm) under quasi-static 4-point bending than the CM constructs (median 2.57 (min 2.5, max 2.6) Nm, p = 0.006). Number of cycles to failure under dynamic 4-point bending was higher for the CM constructs (median 164,272 (min 73,557, max 250,000) cycles) than the AM constructs (median 18,704 (min 14,427, max 33,228) cycles; p = 0.02). Survival analysis showed that 50% of AM plates failed by 18,842 cycles, while 50% CM plates failed by 78,543 cycles. CONCLUSION AND CLINICAL RELEVANCE: Additively manufactured titanium implants, printed to replicate a conventional titanium orthopaedic plate, were more prone to failure in a shorter fatigue period despite being stronger in single cycle to failure. Patient-specific implants made using this process may be brittle and therefore not comparable to CM orthopaedic implants. Careful selection of their use on a case/patient-specific basis is recommended.
dc.description.confidentialfalse
dc.edition.edition2024
dc.format.pagination17-27
dc.identifier.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/37772312
dc.identifier.citationPolak S, Beever L, Wade A, Fukuoka M, Worth AJ. (2024). Biomechanical comparison of titanium alloy additively manufactured and conventionally manufactured plate-screw constructs.. N Z Vet J. 72. 1. (pp. 17-27).
dc.identifier.doi10.1080/00480169.2023.2264805
dc.identifier.eissn1176-0710
dc.identifier.elements-typejournal-article
dc.identifier.issn0048-0169
dc.identifier.urihttps://mro.massey.ac.nz/handle/10179/71260
dc.languageeng
dc.publisherTaylor and Francis Group
dc.publisher.urihttps://www.tandfonline.com/doi/full/10.1080/00480169.2023.2264805?scroll=top&needAccess=true
dc.relation.isPartOfN Z Vet J
dc.rights(c) 2023 The Author/s
dc.rightsCC BY-NC-ND 4.0
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject3D printed
dc.subjectadditively manufactured
dc.subjectconventionally manufactured
dc.subjectfatigue
dc.subjectstrength
dc.subjecttitanium
dc.subjectAnimals
dc.subjectTitanium
dc.subjectAlloys
dc.subjectBone Plates
dc.subjectBone Screws
dc.subjectBiomechanical Phenomena
dc.subjectFracture Fixation, Internal
dc.titleBiomechanical comparison of titanium alloy additively manufactured and conventionally manufactured plate-screw constructs.
dc.typeJournal article
pubs.elements-id480867
pubs.organisational-groupOther

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
480867 PDF.pdf
Size:
2.11 MB
Format:
Adobe Portable Document Format
Description:
Published version.pdf
Loading...
Thumbnail Image
Name:
tnzv_a_2264805_sm9988.mov
Size:
11.13 MB
Format:
Moving Picture Experts Group
Description:
Evidence.mov

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
9.22 KB
Format:
Plain Text
Description:

Collections