MMG sensor for muscle activity detection : low cost design, implementation and experimentation : a thesis presented in fulfilment of the requirements for the degree of Masters of Engineering in Mechatronics, Massey University, Auckland, New Zealand

dc.contributor.authorMa, Martin
dc.date.accessioned2011-01-10T21:24:04Z
dc.date.availableNO_RESTRICTIONen_US
dc.date.available2011-01-10T21:24:04Z
dc.date.issued2010
dc.description.abstractThere is always a demand for cheaper, simpler and more effective human-machine interfaces. Currently, the most reliable and common muscle activity sensor is the EMG. The EMG is an expensive and complex piece of equipment which is far from ideal all round solution. The purpose of this research is to explore various methods of muscle activity detection and using the information gathered design and implement a sensor capable of detecting muscle activation. The major focus is on mechanomyography (MMG), the measurement of mechanical response of muscle during muscle activity. It is well documented that muscles produce low frequency vibrations (5 – 100Hz) during muscle activity. A microphone is able to capture these vibrations when they reach the surface of the skin. The prototype sensor consists of a microphone, microphone preamplifier, low pass Butterworth hardware filter, data acquisition hardware and accompanying data acquisition software. During the experimentation phase, we explored various documented muscle events and phenomena, both general muscle events and ones unique exclusively to MMG. This includes things such as muscle fatigue, exponential relationship between force and vibration, and any other undocumented events. This experimentation also helped determine the effectiveness of the sensor. Testing showed that periods of muscle activity were clearly visible and there was a definitely relationship between the force and vibrations, however there were shortcomings in terms of the sensor design. This included finding a better method of attaching the sensor to the surface of the skin, the dimension deformations of the muscle caused unwanted artefacts in the results and muscle fatigue was not observed. Despite its imperfections, it can be concluded that the design and implementation was a limited success.en_US
dc.identifier.urihttp://hdl.handle.net/10179/2036
dc.language.isoenen_US
dc.publisherMassey Universityen_US
dc.rightsThe Authoren_US
dc.subjectMechanomyography (MMG)en_US
dc.subjectHuman-machine interfaceen_US
dc.subjectMechatronicsen_US
dc.subject.otherFields of Research::290000 Engineering and Technology::290300 Manufacturing Engineering::290301 Robotics and mechatronicsen_US
dc.titleMMG sensor for muscle activity detection : low cost design, implementation and experimentation : a thesis presented in fulfilment of the requirements for the degree of Masters of Engineering in Mechatronics, Massey University, Auckland, New Zealanden_US
dc.typeThesisen_US
massey.contributor.authorMa, Martin
thesis.degree.disciplineMechatronicsen_US
thesis.degree.grantorMassey Universityen_US
thesis.degree.levelMastersen_US
thesis.degree.nameMaster of Engineering (M.E.)en_US
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
02_whole.pdf
Size:
6.98 MB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
01_front.pdf
Size:
82.17 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
896 B
Format:
Item-specific license agreed upon to submission
Description: