Climate-adaptive windcatcher natural ventilation integrated with passive and low-energy technologies: A review of current and future developments

dc.citation.volume284
dc.contributor.authorLi J
dc.contributor.authorCalautit J
dc.contributor.authorJimenez-Bescos C
dc.contributor.authorSong W
dc.contributor.authorRiffat S
dc.contributor.authorChen Q
dc.date.accessioned2025-12-07T22:18:22Z
dc.date.issued2025-10-01
dc.description.abstractThe integration of natural ventilation systems, such as windcatchers, in modern buildings has garnered interest due to rising energy costs and the need for sustainable practices. Windcatchers have been adapted in many regions to enhance indoor air quality and comfort while reducing reliance on mechanical systems and air conditioners. However, extreme climates, such as hot, humid, and cold conditions, pose challenges to effective windcatcher ventilation. Consequently, passive or low-energy cooling, heating and dehumidification technologies have been developed and integrated into windcatchers to improve thermal performance. Despite extensive research, a comprehensive review synthesizing windcatcher integration with passive and low-energy technologies across diverse climates is lacking. Existing studies often focus on specific elements or singular climatic conditions, leaving a gap in understanding the holistic application and optimization of these systems in various environments. This review addresses this gap by analyzing 147 studies on windcatchers and integrating windcatchers with technologies such as evaporative cooling, earth-air heat exchangers, heat pipes, and phase change materials. It evaluates the performance of these systems in hot and arid, temperate, tropical, continental, and polar climates, offering insights into their effectiveness and challenges. Key findings indicate that windcatchers with evaporative cooling effectively reduce indoor temperatures in hot, arid climates, though water scarcity remains a limitation. Earth-air heat exchangers and passive heat recovery technologies enhance efficiency in temperate regions, while indirect evaporative cooling is promising for humidity management in tropical climates. For continental and polar climates, integrating windcatchers with stoves, heat recovery, and solar thermal technologies is proposed, as traditional designs are inadequate in extreme cold. The review offers tailored recommendations for windcatcher designs across climates, guiding future research.
dc.description.confidentialfalse
dc.edition.editionOctober 2025
dc.identifier.citationLi J, Calautit J, Jimenez-Bescos C, Song W, Riffat S, Chen Q. (2025). Climate-adaptive windcatcher natural ventilation integrated with passive and low-energy technologies: A review of current and future developments. Building and Environment. 284.
dc.identifier.doi10.1016/j.buildenv.2025.113436
dc.identifier.elements-typejournal-article
dc.identifier.issn0360-1323
dc.identifier.number113436
dc.identifier.piiS0360132325009114
dc.identifier.urihttps://mro.massey.ac.nz/handle/10179/73917
dc.languageEnglish
dc.publisherElsevier B.V.
dc.publisher.urihttps://www.sciencedirect.com/science/article/pii/S0360132325009114
dc.relation.isPartOfBuilding and Environment
dc.rightsCC BY 4.0
dc.rights(c) 2025 The Author/s
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectWindcatcher
dc.subjectNatural ventilation
dc.subjectBadgir
dc.subjectLow-energy heating
dc.subjectPassive cooling
dc.subjectWind tower
dc.subjectBuilt environment
dc.subjectIndoor environment quality (IEQ)
dc.subjectHeat recovery
dc.subjectDehumidification
dc.titleClimate-adaptive windcatcher natural ventilation integrated with passive and low-energy technologies: A review of current and future developments
dc.typeJournal article
pubs.elements-id608519
pubs.organisational-groupOther

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
608519 PDF.pdf
Size:
11.5 MB
Format:
Adobe Portable Document Format
Description:
Evidence

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
9.22 KB
Format:
Plain Text
Description:

Collections