Reference Intervals for Selected Hematology and Clinical Chemistry Measurands in Temminck's Pangolin (Smutsia temminckii)

dc.citation.volume8
dc.contributor.authorHooijberg EH
dc.contributor.authorLourens K
dc.contributor.authorMeyer LCR
dc.contributor.editorViltrop A
dc.date.accessioned2025-08-29T01:41:15Z
dc.date.available2025-08-29T01:41:15Z
dc.date.issued2021-07-08
dc.description.abstractPangolins are the world’s most trafficked non-human mammals. A significant number of Temminck’s pangolins (Smutsia temminckii) are presented for veterinary care and rehabilitation in southern Africa. Little is known about the physiology and normal health of this species, making diagnosis and medical management difficult. This study aimed to establish reference intervals (RIs) for hematology and plasma clinical chemistry in the Temminck’s pangolin. RIs were generated according to international guidelines using samples from 27 healthy free-living (n = 18) and rehabilitated (n = 9) pangolins. Hematology was performed using the Abaxis VetScan HM5 analyzer with manual differentials; clinical chemistry was performed using heparin plasma on the Abaxis VetScan VS2 and Cobas Integra 400 Plus analyzers. Hematology RIs were: RBC 3.88–8.31 × 1012/L, HGB 73–150 g/L, HCT 26–51%, MCV 59–72 fL, MCH 15.6– 21.4 pg, MCHC 257–325 g/L, RDW 14.3–19.1%, WBC 1.80–10.71 × 109 /L. Vetscan VS2 clinical chemistry RIs were: albumin 27–41 g/L, ALP 26–100 U/L, ALT 25–307 U/L, amylase 267–826 U/L, bilirubin 4–10 µmol/L, calcium 2.1–2.2 mmol/L, globulin 21–55 g/L, glucose 3.8–10.0 mmol/L, phosphate 1.3–2.6 mmol/L, potassium 3.6–5.9 mmol/L, sodium 132–140 mmol/L total protein 52–84 g/L, and urea 5.3–11.4 mmol/L. RIs for creatinine were not calculated as analytical imprecision exceeded analytical performance goals. Cobas Integra clinical chemistry RIs were: albumin 22–33 g/L, ALP 20–104 U/L, ALT 17–291 U/L, amylase 466–1,533 U/L, bilirubin 1–14 µmol/L, calcium 2.0–2.4 mmol/L, creatinine
dc.description.confidentialfalse
dc.identifier.citationHooijberg EH, Lourens K, Meyer LCR. (2021). Reference Intervals for Selected Hematology and Clinical Chemistry Measurands in Temminck's Pangolin (Smutsia temminckii). Frontiers in Veterinary Science. 8.
dc.identifier.doi10.3389/fvets.2021.654529
dc.identifier.eissn2297-1769
dc.identifier.elements-typejournal-article
dc.identifier.number654529
dc.identifier.urihttps://mro.massey.ac.nz/handle/10179/73444
dc.languageEnglish
dc.publisherFrontiers Media S.A.
dc.publisher.urihttp://frontiersin.org/journals/veterinary-science/articles/10.3389/fvets.2021.654529/full
dc.relation.isPartOfFrontiers in Veterinary Science
dc.rights(c) 2021 The Author/s
dc.rightsCC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectTemminck’s ground pangolin
dc.subjectrehabilitation
dc.subjectVetScan VS2
dc.subjectVetScan HM5
dc.subjectCobas Integra 400
dc.subjectreference intervals
dc.subjectconservation medicine
dc.titleReference Intervals for Selected Hematology and Clinical Chemistry Measurands in Temminck's Pangolin (Smutsia temminckii)
dc.typeJournal article
pubs.elements-id502835
pubs.organisational-groupOther

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
502835 PDF.pdf
Size:
2.84 MB
Format:
Adobe Portable Document Format
Description:
Published version.pdf

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
9.22 KB
Format:
Plain Text
Description:

Collections