• Login
    View Item 
    •   Home
    • Massey Documents by Type
    • Journal Articles
    • View Item
    •   Home
    • Massey Documents by Type
    • Journal Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparison of the effects of 7.2% hypertonic saline and 20% mannitol on whole blood coagulation and platelet function in dogs with suspected intracranial hypertension-a pilot study

    Icon
    View/Open Full Text
    artA10.1186Fs12917-017-1108-2.pdf (358.9Kb)
    Icon
    10.1186/s12917-017-1108-2
    Open Access Location
    https://bmcvetres.biomedcentral.com/articles/10.1186/s12917-017-1108-2
     
    Find Full Text
    Abstract
    Hyperosmolar therapy with either mannitol or hypertonic saline (HTS) is commonly used in the treatment of intracranial hypertension (ICH). In vitro data indicate that both mannitol and HTS affect coagulation and platelet function in dogs. The aim of this study was to compare the effects of 20% mannitol and 7.2% HTS on whole blood coagulation using rotational thromboelastometry (ROTEM®) and platelet function using a platelet function analyzer (PFA®) in dogs with suspected ICH. Thirty client-owned dogs with suspected ICH needing osmotherapy were randomized to receive either 20% mannitol (5 ml/kg IV over 15 min) or 7.2% HTS (4 ml/kg IV over 5 min). ROTEM® (EXTEM® and FIBTEM® assays) and PFA® analyses (collagen/ADP cartridges) were performed before (T0), as well as 5 (T5), 60 (T60) and 120 (T120) minutes after administration of HTS or mannitol. Data at T5, T60 and T120 were analyzed as a percentage of values at T0 for comparison between groups, and as absolute values for comparison between time points, respectively.No significant difference was found between the groups for the percentage change of any parameter at any time point except for FIBTEM® clotting time. Within each group, no significant difference was found between time points for any parameter except for FIBTEM® clotting time in the HTS group, and EXTEM® and FIBTEM® maximum clot firmness in the mannitol group. Median ROTEM® values lay within institutional reference intervals in both groups at all time points, whereas median PFA® values were above the reference intervals at T5 (both groups) and T60 (HTS group).Using currently recommended doses, mannitol and HTS do not differ in their effects on whole blood coagulation and platelet function in dogs with suspected ICH. Moreover, no relevant impairment of whole blood coagulation was found following treatment with either solution, whereas a short-lived impairment of platelet function was found after both solutions.
    Citation
    BMC VETERINARY RESEARCH, 2017, 13
    Date
    2017-06-19
    Author
    Yozova ID
    Howard J
    Henke D
    Dirkmann D
    Adamik KN
    Rights
    © The Author(s). 2017. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
    Publisher
    BioMed Central
    Collections
    • Journal Articles
    Metadata
    Show full item record

    Copyright © Massey University
    | Contact Us | Feedback | Copyright Take Down Request | Massey University Privacy Statement
    DSpace software copyright © Duraspace
    v5.7-2023.7-7
     

     

    Information PagesContent PolicyDepositing content to MROCopyright and Access InformationDeposit LicenseDeposit License SummaryTheses FAQFile FormatsDoctoral Thesis Deposit

    Browse

    All of MROCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Copyright © Massey University
    | Contact Us | Feedback | Copyright Take Down Request | Massey University Privacy Statement
    DSpace software copyright © Duraspace
    v5.7-2023.7-7